Katilas skiedroms BIO-CK P Unit (25 – 100 kW)

BIO-CK P Unit (25 – 100 kW)

bio-ck-p-gotfire-unitEquipment for central heating systems BIO-CK PUnit (nominal heat output from 25 to 100 kW) is designed for burning wood chips, wood shavings, olive pits left after olive processing (olive cake) or solid fuel. The boiler system consists of a hot water boiler BIO-CK P, a burner with the fuel feeder and a boiler digital controller. A fuel tank with a feeder should be added to the BIO-CK P Unit. This equipment is designed small and medium sized premises, as a main or as an alternative source of heat, which is currently more and more frequently the user choice. This equipment is characterised by a successful union of the latest technologies and high quality materials as well as by very simple assembly and operation. Thoroughly tested solutions ensure this equipment is safe and reliable. The option of wood chips/olive cake firing in combination with solid fuel firing is a special feature of this equipment. It is manufactured in compliance with EN 303-5 standards and in accordance with ISO 9001/2008.

CHARACTERISTICS OF EQUIPMENT BIO-CK P Unit:

 

  • Designed for firing wood chips and shavings (size G30 to G50), olive pits, i.e. olive cake (remaining after olive processing) or solid fuel, with a power range from 25 to 100 kW.
  • Maximum permitted fuel moisture content is 35%.
  • A wood chip tank and transporter must also be attached.
  • As standard, a wood chip tank is offered as additional equipment, which can be installed inside or outside the premises, or a mixer with the wood chips feeder for installation into the existing tank/room inside the premises.
  • Optionally the boiler can be ordered with burner mounted on left or right side.
  • The fan and electrical heater positioned in the burner, operated by the controller, ignite automatically and maintain the flame.
  • A carefully sized combustion chamber with triple pass flue gas flow assure boiler operation at high efficiency. This makes the boiler very economical in use.
  • The combustion chamber is made out of a high quality sheet metal (5 mm thickness).
  • For solid fuel firing, the large door enables firing with big pieces of wood, as well as easy cleaning and maintenance.
  • Thermal safety system can be connected in through pre-prepared apertures.
  • The body of the boiler is delivered separately from the casing with thermal insulation, the burner with fuel feeder and the boiler digital controller which enables easier transportation and assembly with minimum risk.
  • The basic delivery specification includes a thermometer, cleaning accessories and an ash box but not the draught regulator required for solid fuel firing.
  • The BIO-CK P Unit can be connected either directly to the heating system or through a CAS accumulation tank.
  • An optional extra is the fitting of a flue gas exhaust fan on the boiler outlet.
  • Optionally equipment may be added for turning on / off by a phone or GSM.
  • For firing with pellets, a Cm Pelet-set must be installed, including the changes to the lower boiler door to allow installation of a pellet burner.
  • For firing with oil it is necessary, beside the oil burner, to install an EKO CK/CKB boiler controller. It can be placed on the upper casing lid of the boiler.

STR-35-studeni-2013_NOVI-SPREMNIK1

ADDITIONAL EQUIPMENT:

Obligatory (wood chip firing, without CAS accumulation tank) – Wood chip tank with feeder and mixer for indoor/outdoor installation (volumes 2,8 – 40 m3) or wood chips feeder with mixer for feeding wood chips from the storage room (diameter 2,5 – 5 meters) ; manual 4-way mixing valve; (closed heating system) thermal safety valve, heat exchanger, safety-air vent set (2,5 bar) and expansion vessel; (open heating system) open expansion vessel.

Obligatory (wood chip firing, with CAS accumulation tank) – Wood chip tank with feeder and mixer for indoor/outdoor installation (volumes 2,8 – 40 m3) or wood chips feeder with mixer for feeding wood chips from the storage room (diameter 2,5 – 5 meters) ;  accumulation tank CAS, 3-way thermostatic valve; (closed heating system) thermal safety valve, heat exchanger,
safety-air vent set (2,5 bar) and expansion vessel (open heating system) – open expansion vessel.

Obligatory (solid fuel firing, without CAS accumulation tank) manual 4-way mixing valve; (closed heating system) thermal safety valve, heat exchanger, safety-air vent set (2,5 bar) and expansion vessel (open heating system) – open expansion vessel.

Obligatory (solid fuel firing, with CAS accumulation tank) accumulation tank CAS, 3-way thermostatic valve; (closed heating system) thermal safety valve, heat exchanger, safety-air vent set (2,5 bar) and expansion vessel (open heating system) – open expansion vessel.

Optional – flue gas exhaust fan (the boiler digital controller includes a standard option to control the fan).

HOT WATER SUPPLY REQUIREMENTS:

In order to meet this requirement, the boiler BIO-CK P Unit can be connected to one of our hot water heaters. We suggest a combination with the hanging hot water heaters SKB Digi or LKB Digi, with standing hot water heaters TB or with solar hot water heaters STEB, as well as with combined hot water heaters CAS-B or CAS-BS, if there is a need to build in a solar heating system in the future.